Thermal Analysis

Material behavior under heating, cooling, and mechanical load — thermal transitions, mass loss, and viscoelastic properties (DSC, TGA, STA, DMA, TMA).

Choose a technique depending on what you need to find out about material behavior during heating/cooling or under mechanical load.

Choose an option based on your need

DSC - Differential Scanning Calorimetry

Thermal transitions and specific heat capacity.

When to choose: You need to determine thermal transitions (melting, crystallization, glass transition) or the specific heat capacity of polymers, inorganic materials, or pharmaceuticals, without needing simultaneous mass measurement.

View instruments

STA - Simultaneous Thermal Analysis (TG-DSC)

Mass loss (TGA) and heat flow (DSC), together or standalone.

When to choose: You need sample mass loss during heating (moisture, fillers, decomposition, composite composition) — standalone (TGA) or simultaneous with a DSC signal on the same sample (e.g. quantifying the composition of advanced/composite materials).

View instruments

DMA - Dynamic Mechanical Analysis

Viscoelastic properties of materials.

When to choose: You need the viscoelastic properties of materials — glass transition under load, stiffness/modulus as a function of frequency (polymers, composites, adhesives).

View instruments

TMA - Thermomechanical Analysis

Thermal expansion, softening, penetration.

When to choose: You need the coefficient of thermal expansion (CTE), softening point, or penetration — including thin films and small samples.

View instruments

Consumables - DSC/TGA/STA sample pans

Original and compatible pans/crucibles, on request.

When to choose: You need sample pans (pan/crucible) for your DSC, TGA, or STA instrument — original for the NEXTA series, or a compatible replacement option for an instrument of any brand.

View offering

Quick selection guide
  • I need thermal transitions (melting, glass transition, crystallization) → DSC
  • I need mass loss during heating (moisture, fillers, decomposition) — standalone or with a heat signal on the same sample → STA
  • I need viscoelastic properties / modulus as a function of frequency → DMA
  • I need the coefficient of thermal expansion, penetration, softening of thin films → TMA
  • I need sample pans/crucibles for an existing instrument (original or compatible) → Consumables

Real View® — visual sample observation

A shared option across the entire NEXTA series (STA, DSC, DMA): a high-resolution camera records the sample in real time during measurement, with digital zoom, image analysis, dimension measurement, and color-change analysis (LAB/CMYK/RGB). It provides additional insight alongside standard TG/DSC/DMA curves — useful when it matters to see, not just measure, what is happening to the sample.

Color-change monitoring

Polymers, coatings, food, cosmetics — visual confirmation of color change during heating/cooling.

Oxidative degradation

E.g. oils and lubricants — visual confirmation of the moment of degradation alongside the DSC/TG signal.

Troubleshooting and training

Easier understanding of the causes of unexpected phenomena, and easier explanation of results to colleagues and clients.

Availability by series

Available on NEXTA STA200RV (built-in), NEXTA DSC (DSC600/DSC200), and NEXTA DMA — compatible with model RV-1DMA ("DMA7100" is the older name for NEXTA DMA200). Not available for the TMA7000 series.

Software for NEXTA — data management and automation

The standard control software “Software for NEXTA” is supplied with the entire NEXTA series (STA, DSC, DMA), and is also used with the TMA7000 series; the optional Data I/O package automates data entry and export for laboratories with high sample throughput or strict QA/QC requirements.

Guidance function and ease of use

A guide through measurements according to standard methods, a calibration guide, and simple/standard operating modes — easier for new users, while retaining full functionality for experienced ones. Includes image insertion/editing, touchscreen control, graph display customization, and Mobile Station (remote viewing/control).

Entry automation (barcode)

Optional Data I/O software: scanning a barcode automatically loads the sample name, file name, and measurement conditions — reducing human error when configuring measurements. Note: the barcode reader is not included in the software package and is procured separately.

Mass Upload Template

A CSV template for registering up to 5,000 identification codes at once (sample name, method, batch number) — useful for a large number of samples and measurement conditions; can also be used for individual entry.

Data export and tracking

Thermal analysis results are exported together with accompanying data (test items, batch/serial numbers) in CSV, Excel, or text format — simplifying internal record-keeping and QA/QC reliability. Automation of measurement sequences with an auto-sampler (sample order and count) is also supported.